Newly redesigned MSCT Series »
Humidity

Humidity

Accurate, Reliable, and Long-life Humidity Sensors

ACI humidity sensors are durable, accurate, reliable, and backed by a five-year warranty on the entire device. They can be field calibrated to reduce operating costs and paired with a temperature sensor(s) to reduce installation costs.

Humidity
Humidity Sensors

Product Line Cards

Product catalog
Complete Product Catalog

Product Line Cards

Humidity Products

13 Results
outdoor air RH
Item: 122642

Model: A/RH2-AN-BC-O

Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Outside Air, ± 2% Accuracy, 10,000 Ohm Thermistor w/11K Shunt, Euro Enclosure

$411.00
duct bb
Item: 122834

Model: A/RH3-AN-BC-D-BB

Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Duct, ± 3% Accuracy, 10,000 Ohm Thermistor w/11K Shunt, NEMA 3R Enclosure

$330.00
outdoor air RH
Item: 122840

Model: A/RH3-AN-BC-O

Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Outside Air, ± 3% Accuracy, 10,000 Ohm Thermistor w/11K Shunt, Euro Enclosure

$342.00
room r
Item: 132809

Model: A/RH2-AN-BC-R

Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Room (R), ± 2% Accuracy, 10,000 Ohm Thermistor w/ 11K Shunt

$393.00
duct 4X tt rh
Item: 146074

Model: A/RH3-AN-BC-D-4X

Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Duct, ± 3% Accuracy, 10,000 Ohm Thermistor w/ 11K Shunt, NEMA 4X Enclosure

$350.00
duct bb
Item: 146367

Model: A/RH2-AN-BC-D-BB

Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Duct, ± 3% Accuracy, 10,000 Ohm Thermistor w/ 11K Shunt, NEMA 3R Enclosure

$398.00
room R2
Item: 138114

Model: A/RH1-AN-BC-R2

Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Room (R2), ± 1% Accuracy, 10,000 Ohm Thermistor w/11K Shunt

$707.00
duct eh rh
Item: 134215

Model: A/RH3-AN-BC-D

Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Duct, ± 3% Accuracy, 10,000 Ohm Thermistor w/11K Shunt, Euro Enclosure

$330.00
duct eh rh
Item: 134216

Model: A/RH2-AN-BC-D

Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Duct, ± 2% Accuracy, 10,000 Ohm Thermistor w/11K Shunt, Euro Enclosure

$398.00
room r
Item: 122844

Model: A/RH3-AN-BC-R

Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Room (R), ± 3% Accuracy, 10,000 Ohm Thermistor w/ 11K Shunt

$316.00
room R2
Item: 136807

Model: A/RH3-AN-BC-R2

Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Room (R2), ± 3% Accuracy, 10,000 w/11K Shunt

$316.00
Sun shield
Item: 138214

Model: A/RH2-AN-BC-O-SUN

Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Outside Air, ± 2% Accuracy, 10,000 Ohm Thermistor w/ 11K Shunt, Sun Shield

$833.00

Learn About Our Applications

View guides highlighting the unique sensing solutions ACI offers for some of the most common applications in our industry.

View Our Helpful Calculators

Use ACI’s calculators for Span and Temperature Conversion.