Humidity

Humidity

Accurate, Reliable, and Long-life Humidity Sensors

ACI humidity sensors are durable, accurate, reliable, and backed by a five-year warranty on the entire device. They can be field calibrated to reduce operating costs and paired with a temperature sensor(s) to reduce installation costs.

Humidity
Humidity Sensors

Product Line Cards

Product catalog
Complete Product Catalog

Product Line Cards

Humidity Products

620 Results
outdoor air RH
Item: 122837

Model: A/RH3-AN-O

Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Outside Air, ± 3% Accuracy, 10,000 Ohm Thermistor (Type III), Euro Enclosure

$363.00
duct eh rh
Item: 122880

Model: A/RH3-CP-D

Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Duct, ± 3% Accuracy, 10,000 Ohm Thermistor (Type II), Euro Enclosure

$349.00
room R2
Item: 132612

Model: A/RH2-20K-R2

Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Room (R2), ± 2% Accuracy, 20,000 Ohm Thermistor

$393.00
duct 4X RH
Item: 122624

Model: A/RH2-TTM1K-D-4X-4

Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Duct, NEMA 4X Enclosure, ± 2% Accuracy (NIST Cert), Transmitter w/ 1,000 Ohm RTD (NIST Cert), 4-20mA (Temp Output)

$633.00
Sun shield
Item: 132326

Model: A/RH2-CP-O-SUN

Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Outside Air, ± 2% Accuracy, 10K Ohm Thermistor (Type II), Sun Shield

$882.00
duct eh rh
Item: CONFIGNIST112

Model: A/RH1-1K-NI-D-NIST

Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), 1,000 Ohm Nickel RTD, Duct, Euro Enclosure, NIST Cert

$815.00
Room2 RH Setpoint
Item: 143129

Model: A/RH3-1K-NI-R2S-A09-G5

Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Room (R), ± 3% Accuracy, 1,000 Ohm Nickel RTD, Setpoint 0 to 2K, 55 to 85 Sticker, White

$330.00
duct eh rh
Item: 151386

Model: A/RH2-100-2W-D-NIST

Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA Output (Default), Duct, ± 2% Accuracy, 100 Ohm (Two Wires) RTD, Euro Enclosure, NIST Cert

$488.00
room r
Item: CONFIGNIST87

Model: A/RH2-100-2W-R-NIST

Relative Humidity, RH Outputs: 0-5, 0-10 VDC & 4-20mA (Default), Room (R), ± 2% Accuracy, 100 Ohm (Two Wires) RTD, NIST Cert

$482.00