Platinum RTD Immersion

This product is covered by ACI's Five (5) Year Limited Warranty. Learn more

Product overview

1,000 Ohm (Two Wires) RTD, Immersion, Welded Well, 4", NEMA 3R Enclosure, NIST Cert

Application

  • Chilled Water Systems
  • Hot Water Systems
  • Boilers
  • Pumps
  • Compressor
  • Chillers

Product specifications

Sensor Type:
Platinum RTD
Sensor Curve:
PTC (Positive Temperature Coefficient)
Number Sensing Points:
One
Number Wires:
A/100-2W-I Series and A/1K-2W-I Series: Two (Non-Polarity Sensitive) A/100-3W-I Series and A/1K-3W-I Series: Three (Polarity Sensitive)
Sensor Output @ 0ºC (32ºF):
A/100-xW-I Series: 100 Ohms nominal A/1K-xW-I Series: 1000 Ohms nominal
Sensor Accuracy:
+/- 0.06% Class A (Tolerance Formula: +/- ºC = (0.15ºC + (0.002 * |t|)) where |t| is the absolute value of Temperature above or below 0ºC in ºC) -40ºC (-40ºF): +/- 0.23ºC (+/- 0.414ºF) 0ºC (32ºF): +/- 0.15ºC (+/- 0.27ºF) 200ºC (392ºF): +/- 0.55ºC (+/- 1.00ºF)
Din Standard | Temperature Coeffcient:
DIN EN 60751 (IEC 751) | 3850 ppm / ºC
Stability:
+/- 0.03% after 1000 Hours @ 300ºC (572ºF)
Response Time (63% Step Change):
8 Seconds nominal
Self-Heating | Maximum Operating Current:
100 Ohm RTD: 7 mW/ºC (Still Air) | 5 mA 1K Ohm RTD: 4 mW/ºC (Still Air) | 3 mA
Operating Temperature Range:
-40 to 200ºC (-40 to 392ºF)
Enclosure Temperature Rating:
“-GD” Enclosure: -40 to 115ºC (-40 to 239ºF), Galvanized Steel, NEMA 1 (IP10) “-PB” Enclosure: -30 to 100ºC (-22 to 212ºF), ABS Plastic, UL94-5VB, Plenum Rated “-BB” Enclosure: -40 to 115ºC (-40 to 239ºF), Aluminum, NEMA 3R (IP14) “-4X” Enclosure: -40 to 70ºC (-40 to 158ºF), Polystyrene Plastic, NEMA 4X (IP66)
Storage Temperature Range:
-40 to 85ºC (-40 to 185ºF)
Operating Humidity Range:
10 to 95% RH, non-condensing
Probe Diameter:
0.250" (6.35mm)
Probe Material:
304 Stainless Steel
Thermowell Material | Bore Diameter:
304 Series Stainless Steel | 0.260"
Thermowell Instrument Thread | Process Thread:
½” NPS (National Pipe Straight) Female Thread | ½” NPT (National Pipe Tapered) Male Thread
Fitting Material | Flammability Rating:
Polyamide 66 (High Performance Nylon 66) | UL94-HB
Foam Pad Material | Flammability Rating:
Neoprene/EPDM/SBR Polymer | UL94-HBF; FMVSS-302; MIL-R-6130C
Sensor Threads:
½” NPS (National Pipe Straight) Male Thread
Lead Length | Conductor Size:
14” (35.6 cm) | 22 AWG (0.65mm)
Lead Wire Insulation | Wire Rating:
Etched Teflon (PTFE) Colored Leads | Mil Spec 16878/4 Type E)
Conductor Material:
Silver Plated Copper
Agency Approvals:
CE, UKCA, RoHS2, WEEE
: