This product is covered by ACI's Two (2) Year Limited Warranty. Learn more
Product overview
Analog Input (0-5VDC), Pressure Output (0-10PSI), Dual Valve, Exhausts on Power Failure, Gauge, (0-10V, 0-15V 0-20mA), (0-15PSI, 0-20PSI)
Application
- Three Way Mixing Valve Control
- Chiller Loading
- Pilot Positioner Control
- Pneumatic Valve & Damper Actuator Control
- Fan Vane Control
- DDC Control
- Above Ceiling Applications (Mixing & VAV Boxes)
Product specifications
Supply Voltage:
24 VAC (+/- 10%), 50/60 Hz, 24 VDC (+10% / -5%)
Supply Current:
500 mAAC, 200 mADC Maximum
Input Signal Source:
0-5 VDC @ infinite Ω | 0-10 VDC @ infinite Ω | 0-15 VDC @ infinite Ω | 0-20 mA / 250Ω
Feedback Output Signal Range:
0-5 VDC = Output Span
Output Pressure Range (Jumper Selectable):
Field Calibration Possible: 0 to 20 psig (0-138 kPa) maximum
0-10 psig (0-68.95 kPa), 0-15 psig (0-103.43 kPa) or 0-20 psig (137.9 kPa)
Output Pressure Accuracy:
1% room temperature | 2% full scale across operating temperature range
Manual / Auto Override Switch:
MAN function = output can be varied | AUTO function = output is controlled from input signal
Manual / Auto Override Feedback Output:
Dry Contacts: 24 VDC/VAC @ 1A maximum, N.O. in AUTO operation (Optional: N.O. in MAN operation)
Air Flow:
Supply valves @ 25 psig (172.38 kPa) main/20 psig (137.9 kPa) out, 2300 scim
Branch Line requires 2 in3 / 33.78 cm3 (min.) | Min. 25 ft of 1/4" O.D. poly branch tubing
Filtering:
Furnished with integral-in-barb 80-100 micron filter (Part #PN004) except for EPC2LG which is furnished
with external 5 micron in-line filter (PN021)
Connections | Wire Size:
90° Pluggable Screw Terminal Blocks | 16 (1.31 mm2) to 26 AWG (0.129 mm2
Terminal Block Torque Rating:
0.5 Nm (Minimum); 0.6 Nm (Maximum)
Connections | Pneumatic Tubing Size-Type:
1/4" O.D. nominal (1/8" I.D.) polyethylene
Pneumatic Fitting:
Removable brass fittings for Main & Branchc in machined manifold, Plugged 1/8-27-FNPT gauge port
Gauge Pressure Range (Gauge Models):
0-30 psig (0-200 kPa)
Gauge Pressure Accuracy (Gauge Models):
±2.5% Midscale (±3.5% Full Scale)
Operating Temperature Range:
35 to 120°F (1.7 to 48.9°C)
Operating RH Range:
10 to 95% non-condensing
Storage Temperature Range:
-20 to 150°F (-28.9 to 65.5°C)
Snaptrack Material:
Polyvinyl Chloride (PVC)
Snaptrack Flammability Rating:
UL94 V-0
Product Weight:
EPCG: 0.46 lbs. (0.2069 Kg) | EPC2G: 0.70 lbs. (0.3175 Kg) | EPC2GFS: 0.68 lbs. (0.309 Kg)
EPC2GB: 1 lbs 1 oz. (0.482 Kg) | EPC2GFSB: 0.96 lbs. (0.436 Kg)
Agency Approvals:
RoHS2, WEEE