Relays A/CR Series (Command Relay)

This product is covered by ACI's Five (5) Year Limited Warranty. Learn more

Product overview

Command Relay, Nom. Coil Voltage: 24 VDC, Contact Rating: 12A, Form 1C (SPDT)

Application

  • Start/Stop/Status
  • Motors
  • Pumps
  • Fans
  • Compressors
  • Din Rail Mountable Control Relay
  • Industrial Equipment

Product specifications

Relay Type:
Electromechanical Relay
Nominal Relay Coil Voltage (Rated Current):
A/CR-DC-5A: 23 to 31.2 VDC, 17 mA @ 24 VDC, 60 Hz A/CR-DC-12A: 20 to 31.2 VDC, 17 mA @ 24 VDC, 60 Hz A/CR-12DC-12A: 10 to 15.6 VDC, 33.33 mA @ 12 VDC, 60 Hz A/CR-24AC-10A: 16 to 26.4 VAC, 28.30 mA @ 24 VAC, 60 Hz or 31.30 mA @ 24 VAC, 50 Hz A/CR-115AC-8A: 80 to 132 VAC, 5.35 mA @ 115 VAC, 60 Hz or 5.85 mA @ 115 VAC, 50 Hz A/CR-230AC-8A: 165 to 264 VAC, 2.76 mA @ 230 VAC, 60 Hz or 3.00 mA @ 230 VAC, 50 Hz
Contact Form:
Form 1C (SPDT Contact)
Relay Contact Rating:
A/CR-DC-5A: 5A @ 250 VAC* | 5A @ 125 VAC** 5A @ 30 VDC** | ¼ HP, 120/250/277 VAC A/CR-DC-12A: 12A @ 250 VAC* | 12A @ 250 VAC** | 12A @ 30 VDC** | 1 HP, 120/240/480 VAC (N/O) | ½ HP, 120/240/480 VAC (N/C) A/CR-12DC-12A: 12A @ 250 VAC* | 12A @ 250 VAC** | 12A @ 30 VDC** 1 HP, 120/240/480 VAC (N/O) | ½ HP, 120/240/480 VAC (N/C) A/CR-24AC-10A: 10A @ 250 VAC* | 10A @ 250 VAC** | 10A @ 30 VDC** 1 HP, 120/240/480 VAC (N/O) | ½ HP, 120/240/480 VAC (N/C) A/CR-115AC-8A: 8A @ 250 VAC* | 8A @ 250 VAC** | 8A @ 30 VDC* 1 HP, 120/240/480 VAC (N/O) | ½ HP, 120/240/480 VAC (N/C) A/CR-230AC-8A: 8A @ 250 VAC* | 8A @ 250 VAC** | 8A @ 30 VDC** 1 HP, 120/240/480 VAC (N/O) | ½ HP, 120/240/480 VAC (N/C)
Maximum Contact Switching Voltage:
250 VAC, 30 VDC
Maximum Contact Switching Current:
A/CR-DC-5A: 5A (N/O) / 3A (N/C A/CR-DC-12A: 12 Amps A/CR-12DC-12A: 12 Amps A/CR-24AC-10A: 10 Amps A/CR-115AC-8A: 8 Amps A/CR-230AC-8A: 8 Amps
Status LED Indication:
Red LED “On”: Relay Energized “COM to N/O” | Red LED “O”: Relay De-Energized “Com to N/C”
Relay Electrical Life:
> 30,000 Cycles, typical
Relay Mechanical Life:
> 10,000,000 Cycles, typical
DIN Rail Mounting:
35 mm (U.S. Patent No. 7,416,421)
Operating Temperature Range:
5 to 104ºF (-15 to 40ºC)
Operating Humidity Range:
0 to 95%, non-condensing
Storage Temperature | RH Range:
32 to 104°F (0 to 40°C) | 20% to 85% RH, non-condensing
Enclosure Material | Flammability Rating:
PC/ABS (Polycarbonate/ABS Blend) | UL94-V0
Connections | Wire Size:
Screw Terminal Blocks Relay Coil: 18 to 24 AWG (2.5 mm2 to 0.20 mm2) Copper Wires only Relay Contacts: 12 to 16 AWG (4.0 mm2 to 020 mm2) Copper Wires only
Terminal Block Torque Rating:
4.43 to 5.31 in-lbs. (0.5 to 0.6 Nm)
Agency Approvals:
UL/CUL US Listed (UL 508) Ind. Control Equipment (File # E179139), CE, RoHS, WEEE
Product Weight:
A/CR-DC-5A: 0.135 lbs. (0.061 kg) | A/CR-12DC-12A & A/CR-24AC-10A: 0.150 lbs. (0.068 kg) A/CR-DC-12A, A/CR-115AC-8A & A/CR-230AC-8A: 0.145 lbs. (0.066 kg)
Product Dimensions:
3.283” (83.39 mm) x 1.305” (33.15 mm) x 1.565” (39.75 mm

Related products