WT2630
| Product data sheet: | |
| Product photo: |
The mesh network Series 2000 WT2630 is a battery operated spread spectrum wireless wall temperature sensor or thermostat. The override button (B & C models only) located on the side of the sensor housing can be assigned to a digital output in the Series 2000 family of receivers for occupancy override or similar applications.
The setpoint adjustment (B Model only) can be assigned to an analog output in the Series 2000 receiver. The output will then be used by a controller for a variety of control setpoint ranges (user defined) and other applications such as dimming of light and window blinds control. Series 2000 wireless sensors utilize reliable Spread Spectrum Radio technology. They can be installed easily in minutes eliminating hundreds of feet of wire and saving installation cost while reducing installation labor risks.
The Series 2000 sensor Data-Link LED confirms the data transmission was received by the receiver for fast and reliable positioning of the sensor during installation. There is no need for special wireless installation equipment or survey tools.
Together with the Series 2000 receivers and controllers , the wireless sensors can be used with any LON, BacNet, MODbus, or DDC control system or panel.
The maximum radio transmission distance is dependent on building type. The maximum open- air transmission distance is one mile. In a typical commercial building with steel I-beam construction, concrete floors with reinforcing rod, and metal stud walls, it can be expected that transmissions will penetrate vertically through floors and horizontally through 200 to 500 feet of walls, furniture and air.
The WT2630 is covered by ACI's Two (2) Year Limited Warranty, which is located in the front of ACI'S SENSORS & TRANSMITTERS CATALOG or can be found on ACI's web site, which is: www.workaci.com.
Wireless Sensors
- Wireless Sensors
- Input Modules
- Monitoring Software
- Net Transceivers & Repeaters
- Output Modules
- Sensor Receivers
- Sensors
- DH2630 (Wireless Humidity plus Temperature Duct Sensor option)
- DT2630 (Wireless Duct Temperature Sensors)
- DT2650 (Wireless Flexible Averaging Temperature Sensors)
- FT2630 (Wireless Immersion Temperature Sensors for water and steam applications)
- OA2630 (Wireless Outside Air Temperature & Humidity Sensor)
- OST2630 (Wireless Compact Outside Air Temperature Sensors)
- SSH2636 (Wireless Humidity plus Temperature Sensor option)
- SST2630 (Wireless Remote/Strap-on Temperature Sensor)
- SST5630 (Wireless Remote/Strap-on Temperature Sensor)
- WH2630 (Wireless Wall Humidity plus Temperature Sensor option)
- WT2630 (Wireless Room Temperature Sensors)
RTDs
Thermistors
Semiconductors
Temperature Transmitters
- Temperature Transmitters
- TT100 Page
- TTM100 Page
- TT1K Page
- TTM1K Page
- A/TTM1K (Copper Averaging Bell Box Housing)
- A/TTM1K (Copper Averaging Galvanized Box Housing)
- A/TTM1K (Copper Averaging NEMA 4X Housing)
- A/TTM1K (Copper Averaging Plastic Housing)
- A/TTM1K (Duct Bell Box Housing)
- A/TTM1K (Duct Galvanized Box Housing)
- A/TTM1K (Duct NEMA 4X Housing)
- A/TTM1K (Duct Plastic Housing)
- A/TTM1K (Immersion Bell Box Housing)
- A/TTM1K (Immersion Galvanized Box Housing)
- A/TTM1K (Immersion NEMA 4X Housing)
- A/TTM1K (Immersion Plastic Housing)
- A/TTM1K-O-EH
- A/TTM1K-R
- A/TTM1K-R2
- A/TTM1K-S-4X
- A/TTM1K-S-GD
- A/TTM1K-S-PB
- A/TTM1K-SP
- A/TTM1K-W
- A/TTM1K-W-6'
- TT100 Ohm Low Temp Page
- TT1K Ohm Low Temp Page
- TT100 Ohm High Temp Page
- TT1K Ohm High Temp Page
- Potted Transmitters
- Freezer Sensor
- A/TUC2 (Microprocessor Based)
Humidity
Current
Air Quality
Interface Devices
- Interface Devices
- Analog Input
- 6N1-ISO (Six Analog Average, HI/LO)
- AAR (Adjustable Analog to Relay Output)
- AFP (Analog to Floating Point)
- AIM1 (Analog Isolation Module w/ Rescaling Options)
- AIM2 (Analog Isolation Module w/ Rescaling Options)
- ARM (Analog Rescaling Module)
- ARM2 (Analog Rescaling Module)
- ASA (Analog Signal Amplifier)
- ATL (Four Adjustable Trip Point Relay Output)
- ATP (Analog to PWM Output)
- DRN3.1 (Analog/PWM/Floating Pt. to Resistance)
- DRN4 (Analog/PWM/Floating Pt. to Resistance)
- EPC Series
- MAO (Manual Analog Override Switch w/ Alarm)
- PXP Series
- Pressure or Pulse Width Modulate (PWM) Input
- PTP (Pressure to Analog Signal Interface Device)
- PTP-G (Pressure to Analog Signal w/Gauge Interface Device)
- PTP100 (Pneumatic Sensor to Analog Output)
- EPW Series
- DMUX PWM to 4 Relay Multiplexer (Jumpers)
- DMUX PWM to 8 Relay Multiplexer
- PTA2 (PWM to Analog (Voltage or Current) Output)
- PTA (PWM to Analog (Voltage or Current) Output)
- Resistive Input
- Floating PT. Input
- Low/Line Voltage
- Misc. Devices
- Analog Input
Accessories
- Accessories
- Relays
- Thermowells
- Freeze Stats and Accessories
- Smoke Detection
- A/Capillary Clip
- A/Universal Clip
- A/LCD-R (Loop powered)
- Power Supply (A/PS1.5)
- A/LLS Light Level Sensor
- A/LLS-T Light Level Sensor w/ Transmitter
- A/Glycol Bottle
- LE Series (Transformers)
- Shields and Covers
- 2-5" Hose Clamp
- Mounting Plates