A/CO2-T-RSO
| Product data sheet: | |
| Product instruction: | |
| Product photo: | |
| Product dimensions: | |
The A/CO2-T transmitters monitor both the temperature and carbon dioxide (CO2) levels in industrial and living environments. The concentration of CO2 is a good indication of the indoor air quality (IAQ).
All units come with both a 4-20 mA and a 0-10 VDC analog output for CO2 and a resistive type temperature sensor. The temperature sensor is available with options including Override, Setpoint, and a RJ-14 Communication Jack. By combining both the temperature and CO2 sensors in one package, installation and maintenance is greatly simplified.
The concentration of CO2 is measured using a Single Beam Absorption Infrared Diffusion sampling method. The CO2 transmitter is also equipped with a patented ABC LogicTM (Automatic Background Calibration) software. The ABC LogicTM software virtually eliminates the need for manual calibration in applications where the indoor CO2 level drops to outside levels during unoccupied periods. The ABC LogicTM will not work properly in applications where the space is left unoccupied for less than 4 hours per day or where there are industrial sources of carbon dioxide.
Wireless Sensors
- Wireless Sensors
- Input Modules
- Monitoring Software
- Net Transceivers & Repeaters
- Output Modules
- Sensor Receivers
- Sensors
- DH2630 (Wireless Humidity plus Temperature Duct Sensor option)
- DT2630 (Wireless Duct Temperature Sensors)
- DT2650 (Wireless Flexible Averaging Temperature Sensors)
- FT2630 (Wireless Immersion Temperature Sensors for water and steam applications)
- OA2630 (Wireless Outside Air Temperature & Humidity Sensor)
- OST2630 (Wireless Compact Outside Air Temperature Sensors)
- SSH2636 (Wireless Humidity plus Temperature Sensor option)
- SST2630 (Wireless Remote/Strap-on Temperature Sensor)
- WH2630 (Wireless Wall Humidity plus Temperature Sensor option)
- WT2630 (Wireless Room Temperature Sensors)
RTDs
Thermistors
Semiconductors
Temperature Transmitters
- Temperature Transmitters
- TT100 Page
- TTM100 Page
- TT1K Page
- TTM1K Page
- A/TTM1K (Copper Averaging Bell Box Housing)
- A/TTM1K (Copper Averaging Galvanized Box Housing)
- A/TTM1K (Copper Averaging NEMA 4X Housing)
- A/TTM1K (Copper Averaging Plastic Housing)
- A/TTM1K (Duct Bell Box Housing)
- A/TTM1K (Duct Galvanized Box Housing)
- A/TTM1K (Duct NEMA 4X Housing)
- A/TTM1K (Duct Plastic Housing)
- A/TTM1K (Immersion Bell Box Housing)
- A/TTM1K (Immersion Galvanized Box Housing)
- A/TTM1K (Immersion NEMA 4X Housing)
- A/TTM1K (Immersion Plastic Housing)
- A/TTM1K-O-EH
- A/TTM1K-R
- A/TTM1K-R2
- A/TTM1K-S-4X
- A/TTM1K-S-GD
- A/TTM1K-S-PB
- A/TTM1K-SP
- A/TTM1K-W
- A/TTM1K-W-6'
- TT100 Ohm Low Temp Page
- TT1K Ohm Low Temp Page
- TT100 Ohm High Temp Page
- TT1K Ohm High Temp Page
- Potted Transmitters
- Freezer Sensor
- A/TUC2 (Microprocessor Based)
Humidity
Current
Air Quality
Interface Devices
- Interface Devices
- Analog Input
- 6N1-ISO (Six Analog Average, HI/LO)
- AAR (Adjustable Analog to Relay Output)
- AFP (Analog to Floating Point)
- AIM1 (Analog Isolation Module w/ Rescaling Options)
- AIM2 (Analog Isolation Module w/ Rescaling Options)
- ARM (Analog Rescaling Module)
- ARM2 (Analog Rescaling Module)
- ASA (Analog Signal Amplifier)
- ATL (Four Adjustable Trip Point Relay Output)
- ATP (Analog to PWM Output)
- DRN3.1 (Analog/PWM/Floating Pt. to Resistance)
- DRN4 (Analog/PWM/Floating Pt. to Resistance)
- EPC Series
- MAO (Manual Analog Override Switch w/ Alarm)
- PXP Series
- Pressure or Pulse Width Modulate (PWM) Input
- PTP (Pressure to Analog Signal Interface Device)
- PTP-G (Pressure to Analog Signal w/Gauge Interface Device)
- PTP100 (Pneumatic Sensor to Analog Output)
- EPW Series
- DMUX PWM to 4 Relay Multiplexer (Jumpers)
- DMUX PWM to 8 Relay Multiplexer
- PTA2 (PWM to Analog (Voltage or Current) Output)
- PTA (PWM to Analog (Voltage or Current) Output)
- Resistive Input
- Floating PT. Input
- Low/Line Voltage
- Misc. Devices
- Analog Input
Accessories
- Accessories
- Relays
- Thermowells
- Freeze Stats and Accessories
- Smoke Detection
- A/Capillary Clip
- A/Universal Clip
- A/LCD-R (Loop powered)
- Power Supply (A/PS1.5)
- A/LLS Light Level Sensor
- A/LLS-T Light Level Sensor w/ Transmitter
- A/Glycol Bottle
- LE Series (Transformers)
- Shields and Covers
- 2-5" Hose Clamp
- Mounting Plates