- Contact Us
- Ordering Information
- Distributors
- Technical Info
- News
A/AFS-460
| Product data sheet: | |
| Product instruction: | |
| Product photo: |
The A/AFS-460 series differential pressure switches are general purpose proving switches designed to require a manual operator reset following actuation. These pressure switches can be used to sense either positive, negative, or differential air pressure in HVAC and Energy Management applications which require operator interface.
The A/AFS-460 has an input operating range of 0.40” to 12.0” W.C. with an adjustable setpoint range of 0.40” +/- 0.06” to 12” of W.C.. Each unit contains a diaphragm, calibration spring, and a snap-acting SPST-NC (Manual Reset) switch. The sampling connections are located on each side of the diaphragm. They will accept a 0.25” O.D. rigid metallic tubing via the integral compression ferrule and nut. The enclosure cover guards against accidental contact with the “live switch” terminal screws and the setpoint adjustment screw. It also contains a 1/2” conduit knockout in the cover of the enclosure.
Wireless Sensors
- Wireless Sensors
- Input Modules
- Monitoring Software
- Net Transceivers & Repeaters
- Output Modules
- Sensor Receivers
- Sensors
- DH2630 (Wireless Humidity plus Temperature Duct Sensor option)
- DT2630 (Wireless Duct Temperature Sensors)
- DT2650 (Wireless Flexible Averaging Temperature Sensors)
- FT2630 (Wireless Immersion Temperature Sensors for water and steam applications)
- OA2630 (Wireless Outside Air Temperature & Humidity Sensor)
- OST2630 (Wireless Compact Outside Air Temperature Sensors)
- SSH2636 (Wireless Humidity plus Temperature Sensor option)
- SST2630 (Wireless Remote/Strap-on Temperature Sensor)
- WH2630 (Wireless Wall Humidity plus Temperature Sensor option)
- WT2630 (Wireless Room Temperature Sensors)
RTDs
Thermistors
Semiconductors
Temperature Transmitters
- Temperature Transmitters
- TT100 Page
- TTM100 Page
- TT1K Page
- TTM1K Page
- A/TTM1K (Copper Averaging Bell Box Housing)
- A/TTM1K (Copper Averaging Galvanized Box Housing)
- A/TTM1K (Copper Averaging NEMA 4X Housing)
- A/TTM1K (Copper Averaging Plastic Housing)
- A/TTM1K (Duct Bell Box Housing)
- A/TTM1K (Duct Galvanized Box Housing)
- A/TTM1K (Duct NEMA 4X Housing)
- A/TTM1K (Duct Plastic Housing)
- A/TTM1K (Immersion Bell Box Housing)
- A/TTM1K (Immersion Galvanized Box Housing)
- A/TTM1K (Immersion NEMA 4X Housing)
- A/TTM1K (Immersion Plastic Housing)
- A/TTM1K-O-EH
- A/TTM1K-R
- A/TTM1K-R2
- A/TTM1K-S-4X
- A/TTM1K-S-GD
- A/TTM1K-S-PB
- A/TTM1K-SP
- A/TTM1K-W
- A/TTM1K-W-6'
- TT100 Ohm Low Temp Page
- TT1K Ohm Low Temp Page
- TT100 Ohm High Temp Page
- TT1K Ohm High Temp Page
- Potted Transmitters
- Freezer Sensor
- A/TUC2 (Microprocessor Based)
Humidity
Current
Air Quality
Interface Devices
- Interface Devices
- Analog Input
- 6N1-ISO (Six Analog Average, HI/LO)
- AAR (Adjustable Analog to Relay Output)
- AFP (Analog to Floating Point)
- AIM1 (Analog Isolation Module w/ Rescaling Options)
- AIM2 (Analog Isolation Module w/ Rescaling Options)
- ARM (Analog Rescaling Module)
- ARM2 (Analog Rescaling Module)
- ASA (Analog Signal Amplifier)
- ATL (Four Adjustable Trip Point Relay Output)
- ATP (Analog to PWM Output)
- DRN3.1 (Analog/PWM/Floating Pt. to Resistance)
- DRN4 (Analog/PWM/Floating Pt. to Resistance)
- EPC Series
- MAO (Manual Analog Override Switch w/ Alarm)
- PXP Series
- Pressure or Pulse Width Modulate (PWM) Input
- PTP (Pressure to Analog Signal Interface Device)
- PTP-G (Pressure to Analog Signal w/Gauge Interface Device)
- PTP100 (Pneumatic Sensor to Analog Output)
- EPW Series
- DMUX PWM to 4 Relay Multiplexer (Jumpers)
- DMUX PWM to 8 Relay Multiplexer
- PTA2 (PWM to Analog (Voltage or Current) Output)
- PTA (PWM to Analog (Voltage or Current) Output)
- Resistive Input
- Floating PT. Input
- Low/Line Voltage
- Misc. Devices
- Analog Input
Accessories
- Accessories
- Relays
- Thermowells
- Freeze Stats and Accessories
- Smoke Detection
- A/Capillary Clip
- A/Universal Clip
- A/LCD-R (Loop powered)
- Power Supply (A/PS1.5)
- A/LLS Light Level Sensor
- A/LLS-T Light Level Sensor w/ Transmitter
- A/Glycol Bottle
- LE Series (Transformers)
- Shields and Covers
- 2-5" Hose Clamp
- Mounting Plates



