Gage Pressure Transmitter

Product Data

ACI/GP

Product Description

The ACI/GP is a two-wire, 4-20 mA gage pressure transmitter.  These units have been designed to provide excellent accuracy and reliability in typical industrial grade environments.  Some of the most common applications include: 

·         HVAC and Refrigeration Equiptment
·         Pumps and Compressor Control
·         Industrial Engines
·         Hydraulic Systems 
·         Level Depth Instrumentation

 The ACI/GP pressure transducers are compatible with a wide range of gases and liquids.  They are available in ranges from 0 to 15 up to 0 to 5000 PSIG.  Other ranges may be available upon request.  

All units are accurate to +/- 0.25% of Full Scale (includes non-linearity, hysteresis, and repeatability).  The ACI/GP pressure transmitter offers a combined repeatability and hysteresis factor that is typically below +/- 0.15% of full scale. The GP pressure transducers are both RFI and Reverse Polarity Protected.
 

The pressure port is a 1/4”-18 NPT Male fitting made of 304L & 316L Stainless Steel.  Each unit is approximately 2.45” inches long and weighs approximately 3.3 ounces.  A 2’ shielded cable is supplied for making all of the proper connections.  All of the sensors may be mounted in an optional  NEMA 4 rated enclosure.

All units have a two year factory warranty.

Contact ACI for further information regarding this product. 
Product Specifications

Supply Voltage

+8 to 30 VDC

Accuracy

75 to 3000 psi +/- 0.5% of Full Scale Output  
15 to 50 psi +/- 1.00% of Full Scale Output

Operating Temp. Range

-40 to 221oF (-40 to 105oC)

Proof Pressure

3X Rated Pressure

Output Signal

4-20 mA

Supply Current

25ma Min

Burst Pressure

5X Rated Pressure

Stability 

0.25% FS / Year

Process Fitting

1/4" 18NPT Male 304L & 316L Stainless Steel

Response Time

<1ms

Weight

<3.18 oz (90 grams)

Case

304L and 316L Stainless Steel

EMC Compliance 100 V/M    

 

Pressure Ranges

 Gage psig                Proof psig        Burst psig

     0-15                           40                400
     0-50                          100               750
    0-100                         200              1000
    0-200                         500              2000
    0-500                        1000             3000
   0-1000                       2000             5000

 

Ordering Information

Pressure Range Housing
A/GP- [  ] [  ]
0-15 psig NEMA 4 (optional)
0-50 psig
0-100 psig
0-200 psig
0-500 psig
0-1000 psig

Example: A/GP (0-50) or A/GP (0-100)-NEMA4

Click here to View the PDF Version of this page