| Electrochemical Sensor (Toxic) |
|
|
|
| GAS |
|
AREA |
RADIUS |
|
LOCATION |
| Ammonia |
NH3 |
7500 sq. ft. 775 M2 |
50 ft |
High |
.50 to 1.50 feet below ceiling |
| Carbon Monoxide |
CO |
7500 sq. ft. 775 M2 |
50 ft |
Mid |
4.0 to 6.0 feet above floor |
| Chlorine |
CL2 |
5000 sq. ft. 525 M2 |
40 ft |
Low |
.50 to 1.50 feet above floor |
| Chlorine Dioxide |
CLO2 |
5000 sq. ft. 525 M2 |
40 ft |
Low |
.50 to 1.50 feet above floor |
| Hydrogen |
H2 |
7500 sq. ft. 775 M2 |
50 ft |
High |
.50 to 1.50 feet below ceiling |
| Hydrogen Chloride |
HCL |
5000 sq. ft. 525 M2 |
40 ft |
Mid |
4.0 to 6.0 feet above floor |
| Hydrogen Cyanide |
HCN |
5000 sq. ft. 525 M2 |
40 ft |
Mid |
4.0 to 6.0 feet above floor |
| Hydrogen Sulphide |
H2S |
5000 sq. ft. 525 M2 |
40 ft |
Low |
.50 to 1.50 feet above floor |
| Nitric Oxide |
NO |
5000 sq. ft. 525 M2 |
40 ft |
Mid |
4.0 to 6.0 feet above floor |
| Nitrogen Dioxide |
NO2 |
5000 sq. ft. 525 M2 |
40 ft |
Low |
.50 to 1.50 feet above floor |
| Ozone |
O3 |
5000 sq. ft. 525 M2 |
40 ft |
High |
.50 to 1.50 feet below ceiling |
| Sulphur Dioxide |
SO2 |
5000 sq. ft. 525 M2 |
40 ft |
Low |
.50 to 1.50 feet above floor |
| |
|
|
|
|
|
| Catalytic Pellistor Bead Sensor (Combustibles) |
|
|
|
| GAS |
|
AREA |
RADIUS |
|
LOCATION |
| Acetylene |
|
5000 sq. ft. 525 M2 |
40 ft |
Mid |
5.0 to 6.0 feet above floor |
| Diesel |
|
5000 sq. ft. 525 M2 |
40 ft |
High |
.50 to 1.50 feet below ceiling |
| Ethane |
|
5000 sq. ft. 525 M2 |
40 ft |
Mid |
4.0 to 6.0 feet above floor |
| Gasoline |
|
5000 sq. ft. 525 M2 |
40 ft |
High |
. 50 to 1.50 feet below ceiling |
| Hydrogen |
|
7500 sq. ft. 775 M2 |
50 ft |
High |
. 50 to 1.50 feet below ceiling |
| Methane |
|
5000 sq. ft. 525 M2 |
40 ft |
High |
.50 to 1.50 feet below ceiling |
| Propane |
|
7500 sq. ft. 775 M2 |
50 ft |
Low |
.50 to 1.50 feet above floor |
| N-Butane |
|
5000 sq. ft. 525 M2 |
40 ft |
High |
.50 to 1.50 feet below ceiling |
| N-Octane |
|
5000 sq. ft. 525 M2 |
40 ft |
Low |
.50 to 1.50 feet above floor |
| N-Pentane |
|
5000 sq. ft. 525 M2 |
40 ft |
Low |
.50 to 1.50 feet above floor |
| |
|
|
|
|
|
| Solid State Sensor |
|
|
|
|
|
| GAS |
|
|
|
|
|
| Carbon Monoxide |
CO |
7500 sq. ft. 775 M2 |
50 ft |
Mid |
4.0 to 6.0 feet above floor |
| Propane |
C2H8 |
7500 sq. ft. 775 M2 |
50 ft |
Low |
.50 to 1.50 feet above floor |
| Ammonia |
NH3 |
7500 sq. ft. 775 M2 |
50 ft |
High |
.50 to 1.50 feet below ceiling |
| Freons |
|
7500 sq. ft. 775 M2 |
50 ft |
Low |
50 to 1.50 feet above floor |
| |
|
|
|
|
|
| NDIR Sensor |
|
|
|
|
|
| GAS |
|
|
|
|
|
| Carbon Dioxide |
CO2 |
7500 sq. ft. 775 M2 |
50 ft |
Mid |
4.0 to 6.0 feet above floor |
| Combustible |
CH4 |
5000 sq.ft 525 M2 |
50 ft |
High |
0.5 to 1.50 feet below ceiling |
| Freons |
CxHx |
5000 sq.ft 525 M2 |
50 ft |
Low |
0.5 to 1.5 feet above floor |