The WT2630 is a battery operated spread spectrum wireless room, or wall, temperature sensor or thermostat. The override button (B & C models only) located on the side of the sensor housing can be assigned to a digital output in the Series 2000 family of receivers for occupancy override or similar applications. The setpoint adjustment (B Model only) can be assigned to an analog output in the ACI MESHNET900® receiver. The output will then be used by a controller for a variety of control setpoint ranges (user defined) and other applications such as dimming of light and window blinds control. Series 2000 wireless sensors utilize reliable Spread Spectrum Radio technology. They can be installed easily in minutes eliminating hundreds of feet of wire and saving installation cost while reducing installation labor risks. The Meshnet 900® sensor Data-Link LED confirms the data transmission was received by the receiver for fast and reliable positioning of the sensor during installation. Together with the ACI Wireless receivers and controllers, the wireless sensors can be used with any LON, BacNet, MODbus, or DDC control system or panel. ACI wireless sensors and systems are designed for retrofit HVAC, Building Automation, and industrial systems.  Typical applications include: churches, museums, historical sites, etc.  They are also suitable for flexible office/work station lay outs, auditoriums and conference centers with movable walls, or wide open warehouse spaces.

  • Data Link LEDs confirm data transmission
  • ACI can provide additional set up support before shipping
Add to Cart

Datasheet

Instruction

Product Photo

DOWNLOAD CENTER

Download Data Sheet (catalog page), Instruction, Photo (300 dpi .png file) and/or Wiring Diagram(s).

TECHNICAL SUPPORT

ASK

ACI is dedicated to providing our customers with timely and exceptional support. Didn’t find information you need in our Download Center?
Click the link above to send us an email!

MESHNET 900, DIAGRAM 1
Wireless Solutions with Wireless Sensors
0 Reviews
0
0/5
PoorAdequateExceptional
PoorAdequateExceptional
PoorAdequateExceptional
PoorAdequateExceptional

ACI

Automation Components, Inc. (ACI) is a manufacturer and distributor of sensors for the Heating, Ventilation, and Air Conditioning (HVAC) Industry. ACI was founded in 1991 and is located in Middleton, Wisconsin.

CONTACT

1-888-967-5224 Toll Free

(608) 831-7407 FAX

2305 Pleasant View Road

Middleton, WI 53562

EMail sales@workaci.com

WEBINARS

View ACI latest Webinar here 

SOCIAL MEDIA

ISO9001

ACI is ISO9001 Certified