TSENSE

Gas

TSENSE
$490.00
0

(0)

CO2 Sensor with Temperature, RH & Display TSENSE is an advanced and versatile 3 in 1 transmitter. Designed for installation in the air conditioned zone, it measures CO2 concentration, temperature and humidity in the ambient air. The data is transmitted to a BMS system or stand-alone controller using industry standard output signals and communications protocols, including BACnet™. TSENSE combines all the necessary elements for effective climate control in commercial office buildings, hospitals, hotels, schools and other facilities, allowing for a comfortable and healthy environment for the occupants. It is flexible in design and is suitable for use in many different energy efficient ventilation strategies. 0 to 10 VDC outputs based on 0–2000 ppm, 32-122°F, 0-95% RH. Relay On/Off, based on 1000/900 ppm (CO2). Life expectancy based on 15 years (typical). Backlit LCD displays: CO2 (ppm), Temperature (°F), and Humidity (%RH). Touch display menu system Environmental conditions covered: Carbon Dioxide, Temperature, and Relative Humidity. 

The two part numbers are TSENSE (no display) and TSENSE-LCD (with display).

Carbon Dioxide sensors or transmitters for HVAC, Building Automation Systems, or ANSI/ASHRAE Standard 62.1-2004.  Typical applications include: schools, office buildings, auditoriums, gymnasiums, shopping malls, theatres, demand control ventilation, economizers.  

  • Combines CO2, Temperature, and Relative Humidity into one unit
  • Bacnet or analog outputs
  • User-friendly menu
Add to Cart

Datasheet

Instruction

Product Photo

Additional Information

DOWNLOAD CENTER

Download Data Sheet (catalog page), Instruction, Photo (300 dpi .png file) and/or Wiring Diagram(s).

TECHNICAL SUPPORT

ASK

ACI is dedicated to providing our customers with timely and exceptional support. Didn’t find information you need in our Download Center?
Click the link above to send us an email!

0 Reviews
0
0/5
PoorAdequateExceptional
PoorAdequateExceptional
PoorAdequateExceptional
PoorAdequateExceptional

ACI

Automation Components, Inc. (ACI) is a manufacturer and distributor of sensors for the Heating, Ventilation, and Air Conditioning (HVAC) Industry. ACI was founded in 1991 and is located in Middleton, Wisconsin.

CONTACT

1-888-967-5224 Toll Free

(608) 831-7407 FAX

2305 Pleasant View Road

Middleton, WI 53562

EMail sales@workaci.com

WEBINARS

View ACI latest Webinar here 

SOCIAL MEDIA

ISO9001

ACI is ISO9001 Certified