SL-2000

Accessories

SL-2000
$202.00
0

(0)

The SL-2000 series duct smoke detectors will provide early detection of smoke and products of combustion present in the air moving through HVAC ducts in any commercial, industrial, or residential application. These devices are designed for the prevention of smoke re-circulation by the air handling systems, fans, and blowers.  The SL-2000 is designed and built to meet all local requirements, as well as the NFPA regulations regarding duct smoke dectors.  Output terminals are provided for remote accessories such as horns, strobes, remote status indicators, and test/reset key switches or pushbuttons.  The Ionization and Photoelectric detector heads are interchangeable.  Air sampling is accomplished via two tubes that protrude into the duct.  An exhaust tube with a standard length of 7" is supplied in the installation kit with the unit.  Once the duct size is determined, a sampling tube must be ordered.  Four standard sizes including a 1', 2.5', 5', and 10' lengths can be ordered and cut to the correct size of the duct.  The SL-2000 provides two sets of 10A form "C"  and one set of a 2A form "A" alarm contacts, along with one set of 10A form "C" trouble contacts for monitoring head removal and supply voltage failure.  The SL-2000 is covered by ACI's Two (2) Year Limited Warranty.

  • "No-Tools Required" front or rear loading and removing sampling/exhaust tubes
  • Interconnect up to 30 units for common functions
  • Magnet test capability (magnet included)
  • Unit includes green pilot and red alarm visual indicators

Part Numbers and Accessories

Add to Cart

Datasheet

Instruction

Product Photo

DOWNLOAD CENTER

Download Data Sheet (catalog page), Instruction, Photo (300 dpi .png file) and/or Wiring Diagram(s).

TECHNICAL SUPPORT

ASK

ACI is dedicated to providing our customers with timely and exceptional support. Didn’t find information you need in our Download Center?
Click the link above to send us an email!

0 Reviews
0
0/5
PoorAdequateExceptional
PoorAdequateExceptional
PoorAdequateExceptional
PoorAdequateExceptional

ACI

Automation Components, Inc. (ACI) is a manufacturer and distributor of sensors for the Heating, Ventilation, and Air Conditioning (HVAC) Industry. ACI was founded in 1991 and is located in Middleton, Wisconsin.

CONTACT

1-888-967-5224 Toll Free

(608) 831-7407 FAX

2305 Pleasant View Road

Middleton, WI 53562

EMail sales@workaci.com

WEBINARS

View ACI latest Webinar here 

SOCIAL MEDIA

ISO9001

ACI is ISO9001 Certified