Log In

Enter your WorkACI username.

Enter the password that accompanies your username.

Q5 Series

Gas

Q5 Series
$0.00
5

(1)

The Q5 Series is a microprocessor based “smart” gas transmitter. It is paired with either an electrochemical gas sensor for toxic gases, or a catalytic bead sensor for combustible gases. Pre-calibrated sensors can be purchased and installed by the user, thereby reducing calibration costs and minimizing downtime. The user can select from numerous display options, including relay status, time, TWA, STEL, concentration, or nothing at all. All programming and calibration is nonproprietary and is accessed through a user selectable password which protects system integrity. The Q5 series is covered by ACI's Two (2) Year Limited Warranty.  

Replacement Sensors are also available here.

GASES COVERED: Acetone, Ammonia, Arsine, Benzene, Iso-Butane, Butanol, n-Butane, Carbon Dioxide, Carbon Monoxide, Chlorine, Chlorine Dioxide, Combustibles, Diborane, Ethylene, Ethylene Oxide, Germaine, Hydrogen, Hydrogen Bromide, Hydrogen Chloride, Hydrogen Cyanide, Hydrogen Sulphide, Methane, Methanol, Nitric Oxide, Nitrogen Dioxide, Oxygen, Ozone, Iso-Pentane, Phosphine,  Propane, Silane, Sulphur Dioxide

ACI combustible gas sensors or transmitters are designed for HVAC, Building Automation Systems, or Industrial applications.

Toxic gas sensors or transmitters for HVAC, Building Automation Systems, or OSHA standards.  Typical applications: mechanical rooms, loading docks, service garages, laboratories.

ACI nitrogen dioxide sensors or transmitters are designed for HVAC, Building Automation Systems, or OSHA standards.  Typical applications include: parking garages, arenas, kitchens, laundry rooms, warehouses, loading docks, service garages, school bus parking areas.

ACI carbon monoxide sensors or transmitters are designed for HVAC, Building Automation Systems, or OSHA standards.  Typical applications include: parking garages, arenas, kitchens, laundry rooms, warehouses, loading docks, service garages, and school bus parking areas.  

  • Pre-calibrated sensors available for easy replacement without calibration
  • Digital display of TWA, STEL, concentration and relay status
  • Non-proprietary set-up and calibration procedures
  • Three on board user programmable relays
  • Removable terminal blocks for easy wiring
  • Sensor housing sealed from electronics
  • NEMA 4X enclosure with knock-outs

Enclosures available to order separately: 
Enclosure w/Pump-Thru Cap Kit
Enclosure w/Splash Guard Kit
Enclosure w/Duct Mount Kit

Choose a gas

Add to Cart

Datasheet

Instruction

Product Photo

PDF Drawing

Additional Information

User Manual

DOWNLOAD CENTER

Download Data Sheet (catalog page), Instruction, Photo (300 dpi .png file) and/or Wiring Diagram(s).

TECHNICAL SUPPORT

ASK

ACI is dedicated to providing our customers with timely and exceptional support. Didn’t find information you need in our Download Center?
Click the link above to send us an email!

1 Reviews
5
5/5
PoorAdequateExceptional
PoorAdequateExceptional
PoorAdequateExceptional
PoorAdequateExceptional

ACI

Automation Components, Inc. (ACI) is a manufacturer and distributor of sensors for the Heating, Ventilation, and Air Conditioning (HVAC) Industry. ACI was founded in 1991 and is located in Middleton, Wisconsin.

CONTACT

1-888-967-5224 Toll Free

(608) 831-7407 FAX

2305 Pleasant View Road

Middleton, WI 53562

EMail sales@workaci.com

WEBINARS

View ACI latest Webinar here 

SOCIAL MEDIA

ISO9001

ACI is ISO9001 Certified