Q-CONTROLLER

Gas

Q-CONTROLLER
$3,730.00
0

(0)

The new Q-Controller system uses an RS-485 communication protocol that accommodates 128 channels through four digital ports. In addition, there are 128 analog inputs from any 4-20mA device and 128 4-20mA outputs as well. There are also up to 128 binary inputs and 128 binary outputs. The system
communicates wirelessly for programming and downloading of data through your smartphone or tablet device. Input/output boxes can be installed anywhere in the RS-485 network for ease of installation of additional sensors. A touch screen graphic display is used for programming. All relevant gas detection data, such as relay status, historical data, location and addresses of sensors are displayed by scrolling through multiple screens. The controller has a scheduler that can programmed to activate relays and deactivate relays (4, 10 Amp SPDT relays on main board) several times a day based on a frequency of day, weekday or weekend only. It also has an auto configure program that searches for connected devices. As the unit can accept any 4-20mA signal, it is ideal for additional monitoring such as temperature, humidity and other parameters. Several Q-Controllers can be connected together to a centralized system that will display gas detection concentrations of an entire facility. Remote monitors are an optional item that can be used to observe the concentration of gases prior to entering the space.
The Q-Controller is covered by ACI's Two (2) Year Limited Warranty. The warranty can be found in the front of ACI's Sensors & Transmitters catalog, as well as on ACI's web site, www.workaci.com

Add to Cart

Datasheet

Product Photo

Additional Information

DOWNLOAD CENTER

Download Data Sheet (catalog page), Instruction, Photo (300 dpi .png file) and/or Wiring Diagram(s).

TECHNICAL SUPPORT

ASK

ACI is dedicated to providing our customers with timely and exceptional support. Didn’t find information you need in our Download Center?
Click the link above to send us an email!

0 Reviews
0
0/5
PoorAdequateExceptional
PoorAdequateExceptional
PoorAdequateExceptional
PoorAdequateExceptional

ACI

Automation Components, Inc. (ACI) is a manufacturer and distributor of sensors for the Heating, Ventilation, and Air Conditioning (HVAC) Industry. ACI was founded in 1991 and is located in Middleton, Wisconsin.

CONTACT

1-888-967-5224 Toll Free

(608) 831-7407 FAX

2305 Pleasant View Road

Middleton, WI 53562

EMail sales@workaci.com

WEBINARS

View ACI latest Webinar here 

SOCIAL MEDIA

ISO9001

ACI is ISO9001 Certified