The PowerScout™ is an intuitive, networked power meter designed to monitor and provide consumption data. It also monitors voltage, current, power, energy, and many other electrical parameters on single and three phase circuit installations. Data updates occur once every second to ensure timely and accurate results. Convenient size and versatility make it the ideal device for monitoring and diagnosing consumption data in commercial, industrial, government, and retail environments. The PowerScout™ features field-selectable Modbus or BACnet® protocols, digital pulse outputs, interchangeable split-core or RoCoil™ current transformers, and direct USB setup. A type AB USB cable may be used between a PC and a PS3037 meter and is the preferred method for setting up a PS3037 with Modbus protocols. The USB cable will also power the meter when connected to a PC.  USB cables are not included and must be purchased separately. Connect via serial RS-485 or optional Ethernet and use the optional back-lit display to verify setup and check real time values. The PowerScout™ makes over 50 total electrical measurements, including energy and demand. Revenue-grade ANSI C12.20-2010 qualified Class 0.2 performance. Ideal for high-accuracy applications like demand response or tenant submetering. The PS24 adds 24 channels for multi-circuit monitoring.  (See the "Additional Information" document below for a full description of the PowerScout™ 3037 and PS24 features).

  • Revenue-grade ANSI C12.20-2010 Qualified Class 0.2 performance
  • Field-selectable Modbus or BACnet® protocols
  • USB configuration via simple USB-to-PC connection
  • Optional back-lit LCD verifies setup and checks real-time values
  • Can be equipped with Split-Core CTs or Rogowski Flex CTs
Add to Cart

Datasheet

Instruction

Product Photo

Additional Information

DOWNLOAD CENTER

Download Data Sheet (catalog page), Instruction, Photo (300 dpi .png file) and/or Wiring Diagram(s).

TECHNICAL SUPPORT

ASK

ACI is dedicated to providing our customers with timely and exceptional support. Didn’t find information you need in our Download Center?
Click the link above to send us an email!

0 Reviews
0
0/5
PoorAdequateExceptional
PoorAdequateExceptional
PoorAdequateExceptional
PoorAdequateExceptional

ACI

Automation Components, Inc. (ACI) is a manufacturer and distributor of sensors for the Heating, Ventilation, and Air Conditioning (HVAC) Industry. ACI was founded in 1991 and is located in Middleton, Wisconsin.

CONTACT

1-888-967-5224 Toll Free

(608) 831-7407 FAX

2305 Pleasant View Road

Middleton, WI 53562

EMail sales@workaci.com

WEBINARS

View ACI latest Webinar here 

SOCIAL MEDIA

ISO9001

ACI is ISO9001 Certified