CTS-M5

Gas

CTS-M5
$0.00
0

(0)

The CTS-M5 Series has a microprocessor based transmitter. It uses an Electrochemical gas sensor to monitor a variety of gases. The CTS-M5 Series offers great value since it includes many standard features that can only be found as expensive options in other manufacturer's models.  A digital display (LCD), push-button programming and on-board meter jacks are all standard. The transmitter provides an analog output of 4-20 mA DC or 2-10 VDC, proportional to the measured gas range, for transmission to the Building Automation System.  The CTS-M5 Series offers flexibility and simplicity in one package.  The relay setpoints may be seen as increasing or decreasing actuation simply by adjusting the deadband relationship. Set the deactuation point above the actuation setpoint and the CTS-M5 will automatically alarm on decreasing concentrations.  Plus, calibration is extremely simple.  First, apply the calibration gas and then adjust the potentiometer to the desired reading on the display.  The CTS-M5 Series is covered by ACI's Two (2) Year Limited Warranty. Toxic gas sensors or transmitters for HVAC, Building Automation Systems, or OSHA standards. Typical applications: mechanical rooms, loading docks, service garages, laboratories.

  • Reliable sensor performance (Electrochemical)
  • Push button programming
  • Relay option

Choose a Gas

Choose an enclosure

Choose option-Leave blank if no relay is needed

Add to Cart

Datasheet

Instruction

Product Photo

PDF Drawing

product

DXF Drawing

DOWNLOAD CENTER

Download Data Sheet (catalog page), Instruction, Photo (300 dpi .png file) and/or Wiring Diagram(s).

TECHNICAL SUPPORT

ASK

ACI is dedicated to providing our customers with timely and exceptional support. Didn’t find information you need in our Download Center?
Click the link above to send us an email!

0 Reviews
0
0/5
PoorAdequateExceptional
PoorAdequateExceptional
PoorAdequateExceptional
PoorAdequateExceptional

ACI

Automation Components, Inc. (ACI) is a manufacturer and distributor of sensors for the Heating, Ventilation, and Air Conditioning (HVAC) Industry. ACI was founded in 1991 and is located in Middleton, Wisconsin.

CONTACT

1-888-967-5224 Toll Free

(608) 831-7407 FAX

2305 Pleasant View Road

Middleton, WI 53562

EMail sales@workaci.com

WEBINARS

View ACI latest Webinar here 

SOCIAL MEDIA

ISO9001

ACI is ISO9001 Certified