A/DLP Single Span/Output

Pressure

A/DLP Single Span/Output
$290.00
0

(0)

Ranges: See Attributes

Outputs: 4-20 mA, 0-5 VDC, 0-10 VDC

Display: See Attributes

The DLP Series is based on a piezoresistive, silicon sensing element which senses Differential Pressure and provides an analog output.  This series combines the best attributes and product flexibilities of the two product lines that it replaces (A/LP2 and A/DP2).  Not only does it tap into ACI’s past tradition of providing an accurate and dependable device, it has been enhanced in several important aspects. 

The hinged cover on the DLP can be easily opened using the integrated locking tab on the side of the enclosure.  This allows for easy access to the zero function and field selectable ranges and outputs. The DLP Series also includes an optional five digit, easy to read display which aids in initial setup/installation, troubleshooting, and local monitoring.  The cord grip ­fitting provides strain relief and easy access to the color coded, spring loaded terminal blocks.

The standard accuracy of this series is  ±0.25% and N.I.S.T. certification is available as well (see data sheet order grid).   Analog outputs include 0-5 and 0-10 VDC, or 4-20mA which correlate to a uni or bidirectional pressure range from 0-0.1” up to 0-40” of water column, depending on your model selection.  The addition of a Pitot Tube and Din Rail Clip further enhances the overall flexibility of this device.

Applications Include: building and duct static pressure, filter monitoring, air flow measurement, and process control.

Choose a Pressure Range for your DLP

Choose your unit of Measure

Bidirectional or Unidirectional

Choose if your unit has a display

Choose Pitot Tube and Options

Choose the Output for the Unit

Choose your N.I.S.T. Options

Choose the housing for your DLP

Add to Cart

Datasheet

Instruction

Product Photo

DOWNLOAD CENTER

Download Data Sheet (catalog page), Instruction, Photo (300 dpi .png file) and/or Wiring Diagram(s).

TECHNICAL SUPPORT

ASK

ACI is dedicated to providing our customers with timely and exceptional support. Didn’t find information you need in our Download Center?
Click the link above to send us an email!

0 Reviews
0
0/5
PoorAdequateExceptional
PoorAdequateExceptional
PoorAdequateExceptional
PoorAdequateExceptional

ACI

Automation Components, Inc. (ACI) is a manufacturer and distributor of sensors for the Heating, Ventilation, and Air Conditioning (HVAC) Industry. ACI was founded in 1991 and is located in Middleton, Wisconsin.

CONTACT

1-888-967-5224 Toll Free

(608) 831-7407 FAX

2305 Pleasant View Road

Middleton, WI 53562

EMail sales@workaci.com

WEBINARS

View ACI latest Webinar here 

SOCIAL MEDIA

ISO9001

ACI is ISO9001 Certified