Log In

Enter your WorkACI username.

Enter the password that accompanies your username.

A/CO2-R2XX-T (Temp)

Gas

A/CO2-R2XX-T (Temp)
$0.00
0

(0)

The ACI CO2 (A/CO2-R2) room transmitter monitors the carbon dioxide (CO2) levels in industrial, school, and office-type environments. The concentration of CO2 is a strong indication of the overall indoor air quality.  The A/CO2 Series is based on a single beam, non-dispersive infrared technology and is a cost-efficient solution for measuring carbon dioxide (CO2) levels for building climate control. In addition, ABC software eliminates the need for manual calibration. Carbon Dioxide concentration is measured up to 2,000 ppm and is converted into proportional analog outputs. The factory default output is 4-20 mA, whereas 0-5 VDC and 0-10 VDC outputs are able to be field selected via integral dip switches. Thermistor temperature outputs, along with setpoint and override, are available as options for room configurations. The A/CO2 Series provides data which can be used in conjunction with a Building Automation System or Demand Control Ventilation to decrease energy consumption while creating a healthier indoor climate. The A/CO2 Series is covered by ACI's Five (5) Year Limited Warranty. Carbon Dioxide sensors or transmitters for HVAC, Building Automation Systems, or ANSI/ASHRAE Standard 62.1-2007. Typical applications include: schools, office buildings, auditoriums, gymnasiums, shopping malls, theatres, Demand Control Ventilation, or economizers.

  • Universal outputs (0-5 VDC, 0-10 VDC, and 4-20 mA)
  • 0 to 2,000 ppm range (default on each unit)
  • Infrared Sensing Technology (Based on single beam)
  • Outputs, Setpoints, Override available for each unit
  • ABC Logic Automatic Calibration Software
  • Numerous thermistor temperature options 

Select the thermistor you require

Select your Slide Pot

Add to Cart

Datasheet

Instruction

Product Photo

DOWNLOAD CENTER

Download Data Sheet (catalog page), Instruction, Photo (300 dpi .png file) and/or Wiring Diagram(s).

TECHNICAL SUPPORT

ASK

ACI is dedicated to providing our customers with timely and exceptional support. Didn’t find information you need in our Download Center?
Click the link above to send us an email!

Lorem Ipsum is simply dummy text of the printing and typesetting industry. Lorem Ipsum has been the industry's standard dummy text ever since the 1500s, when an unknown printer took a galley of type and scrambled it to make a type specimen book. It has survived not only five centuries, but also the leap into electronic typesetting, remaining essentially unchanged.
0 Reviews
0
0/5
PoorAdequateExceptional
PoorAdequateExceptional
PoorAdequateExceptional
PoorAdequateExceptional

ACI

Automation Components, Inc. (ACI) is a manufacturer and distributor of sensors for the Heating, Ventilation, and Air Conditioning (HVAC) Industry. ACI was founded in 1991 and is located in Middleton, Wisconsin.

CONTACT

1-888-967-5224 Toll Free

(608) 831-7407 FAX

2305 Pleasant View Road

Middleton, WI 53562

EMail sales@workaci.com

WEBINARS

View ACI latest Webinar here 

SOCIAL MEDIA

ISO9001

ACI is ISO9001 Certified